THICKER COATINGS
-
Thicker coatings than those set out in BS EN ISO 1461 can give additional protection for use in particularly aggressive environments and can be specified in conjunction with BS EN ISO 1461. It should, however, be emphasised that, for most applications, thicker coatings are rarely necessary.

Grit blasting prior to galvanizing is usually the most appropriate method and a requirement for a nominal coating thickness of 1000 g/m²(140µm) has been successfully specified for steel of 6mm section thickness. For structural steelwork, it is advisable to ascertain whether thicker coatings could be achieved through their greater section thickness and without grit blasting. 
spacer

Achieving thicker coatings through specification of a reactive steel is normally only appropriate for specific applications.

Specification of thicker coatings must only be made following consultation with the galvanizer concerning viability and the means by which they will be achieved.